- Vacuum tube collector CPC Nero
- Flat-plate collector PremiumPlus AL
- In-roof-collectors PremiumFlair AL
- Flat-plate collector Silversun
- Solar set configurator
- Solar DHW heater NANOSOL
- Solarpipe Nano
- Solar controllers
- Solar accessories
- Collector installation kits
Vacuum tube collector CPC Nero
( 2 products )Product description of vacuum tube collectors CPC Nero
Solarbayer CPC collectors are available either with 12 or 18 tubes. Our evacuated tube collector CPC stands out from the crowd of standard tube collectors because of its excellent optical and technical properties. The 58mm thick glass tubes guarantee a high yield of solar energy and the replacement of the single tubes is really simple. Due to its ingenious design the tube collector achieves highest solar yield, especially in extreme fields of application and when high temperatures are required. A special CPC reflector behind the tubes with an optimally located focus point directs solar radiation onto the absorber tubes in an ideal way, even when the radiation angles are different.
Only high quality material is used for the manufacturing of our CPC collector, e.g. proved and tested full copper double harp tubes and manifolds. Due to the smart connection of the single tubes to the flow and return line a steady hat dissipation of all single tubes is ensured. The special inductive annular gap hard soldering method guarantees an absolutely secure connection of the harp to the manifold. Therefore, a durable construction is guaranteed. Thus, the known Solarbayer quality and long service life is guaranteed for the CPC collector as well.
- highest performance due to vacuum tubes
- perfect if higher temperatures are required
- high selective absorber coating
- perfect focal point due to CPC reflector
- integrated return pipe, thus one-sided connection possible
- high performance even when the lighting conditions are diffuse
- tubes are easy to change without draining the system
- long operating life of the tubes, the vacuum is hermetically sealed against environmental influences
-
aluminium casingnoble design in black
-
vacuum tube pipes with absorber58mm thick vacuum tube pipes with high selective coating AL-N/AL absorber and double-shell safety glass
-
U-pipescopper U-pipes inside the tubes
-
CPC reflectorHighly polished CPC reflector for perfect focal point
-
copper collector pipesevery U-pipe is connected to the Tichelmann principle for a regular flow
-
thermal insulationcompressed rock wool insulation
-
additional return flow pipe integretedallows a connection on one side of a collector row
collector type
|
CPC 12
|
CPC 18
|
|
type of mounting
|
on roof (pitched/flat roof))
|
||
gross surface area
|
m² |
2,18
|
3,26
|
aperture surface area
|
m² |
1,89
|
2,83
|
number of collector tubes
|
12
|
18
|
|
height
|
mm |
1626
|
1626
|
width incl. connections
|
mm |
1420
|
2080
|
width
|
mm |
1342
|
2002
|
depth
|
mm |
126
|
126
|
weight unfilled
|
kg |
41
|
63
|
fluid capacity
|
L |
1,56
|
2,33
|
max. operating pressure
|
bar |
6
|
6
|
stagnation temperature
|
°C |
280
|
280
|
annual collector yield (EN 12975, 25°C location Würzburg)
|
kWh |
1546
|
2305
|
annual collector yield (EN 12975, 50°C location Würzburg)
|
kWh |
1288
|
1921
|
annual collector yield (EN 12975, 75°C location Würzburg)
|
kWh |
1084
|
1563
|
peak output (G=1000W/m², η0) (*1)
|
W |
1284
|
1914
|
conversion factor (*1)
|
η0 |
0,575
|
|
heat transfer coefficient a1 (*1)
|
W/(m²K) |
0,1250
|
|
heat transfer coefficient a2 (*1)
|
W/(m²K) |
0,004
|
|
incidence angle modifier IAM50
|
0,96
|
||
collector tube glass
|
safety glass
|
||
connections
|
mm |
CU 18 x 1,0
|
|
absorber with vacuum tube
|
U-shaped tube CU
|
||
absorber coating
|
high selective AL-N/AL
|
||
CPC-reflector
|
highly polished
|
||
casing
|
Aluminum
|
||
thermal insulation
|
compressed rock wool
|
||
according to standard
|
DIN EN 12975
|
||
hydraulic connection
|
maximum 5 collectors in a row
|
||
distance between collectors
|
mm |
70
|
|
permissible collector tilt
|
15° - 65° (stand-kit available)
|
||
min. recommended buffer storage tank volume
|
50 L/m² collector surface
|