- Stratification buffer tank SLS
- Heating buffer tank P8 / PS8
- Buffer tank P
- Heat pump storage tank WP
- System cylinder for heat pumps WP
- Heat pump storage tank WP-VA
- Solar DHW tank SKL
- Solar domestic hot water tank TWB
- Hygienic stratification buffer tank HSK-SLS
- Hygienic stratification storage tank HSK-ÖKO
- Electric heating elements
- Tank accessories
- Special made storage tanks
Solar DHW tank SKL
( 6 products )SKL-750, twin coil DHW storage cylinder
(Artikelnummer: 100507000)
Item no. 100507000
SKL-1000, twin coil DHW storage cylinder
(Artikelnummer: 100510000)
Item no. 100510000
Inside enamelled solar domestic hot water tank for central hot water supply, two heat exchangers with big surface, prepared for auxiliary heating by an electrical element.
Available standard sizes 200, 300, 400, 500, 750 und 1000 litres.
Perfectly aligned for solar systems
Hygiene in the high performance DHW tank SKL is guaranteed by heating up the special heat exchangers during solar operation. The high power solar exchanger is decisive for the performance of the solar system. The temperature in the solar return line of the SKL is up to 15°C lower than with regular DHW tanks and with their regular heat exchangers due to its arrangement far down of the tank. Thus, the efficiency factor of the solar system and the performance of the collectors is increased up to 15%.
Due to the supplementary heat exchanger, which is located in the upper part of the tank, the heating value is guaranteed even when heating up with a condensing boiler. Therefore, the DHW output capacity of our tanks is a lot higher than the output capacity of regular solar tanks. An interconnection of both heat exchangers is possible to get an high performance anti-legionella tank, p. ex. for the application with heat pumps or in the hotel industry.
- perfectly aligned for all solar systems
- also suitable for condensing technology
- twin coil tank, two plain tube heat exchangers (solar and heating)
- high quality steel S235JR
- internal corrosion protection with double enameling (Made in Germany)
- magnesia anode installed
- insulation for SKL 200 to SKL 500: PU rigid foam (non-removable), insulation thickness approx. 50 mm
- insulation for SKL 750 and SKL 1000: removable flexible foam insulation WLG 0,039, insulation thickness approx. 75 mm
- silver PVC jacket, fire protection classification: B2
- installation of an electric heating element possible
Solar DHW tank SKL | 200 | 300 | 400 | 500 | 750 | 1000 | |
nominal capacity | L | 209 | 305 | 411 | 454 | 740 | 926 |
height with insulation [A] | mm | 1265 | 1515 | 1630 | 1805 | 1870 | 2120 |
height without insulation [B] | mm | - | - | - | - | 1805 | 2055 |
tilted height | mm | 1450 | 1650 | 1780 | 1960 | 1900 | 2150 |
diameter with insulation [C] | mm | 610 | 650 | 700 | 750 | 950 | 950 |
diameter without insulation [D] | mm | - | - | - | - | 790 | 790 |
insulation thickness non-removable solid foam | mm | 50 | 50 | 50 | 50 | - | - |
insulation thickness removable solid foam | mm | - | - | - | - | 80 | 80 |
jacket | PVC, silver | ||||||
max. operating pressure tank | bar | 10 | 10 | 10 | 10 | 10 | 10 |
max. operating temperature tank | °C | 95 | 95 | 95 | 95 | 95 | 95 |
weight | kg | 92 | 114 | 149 | 173 | 238 | 250 |
max. size of electric heating element (optional) | kW | 4,5 | 4,5 | 4,5 | 6 | 9 | 9 |
standby heat loss according to EN 12897:2006 | 200 | 300 | 400 | 500 | 750 | 1000 | |
standby heat loss | kWh/24h | 1,42 | 1,68 | 1,97 | 2,18 | 3,17 | 3,48 |
energy efficiency class | B | B | C | C | -- | -- | |
heating label | -- | -- |
specification heat exchanger top | 200 | 300 | 400 | 500 | 750 | 1000 | |
heating surface | m² | 0,9 | 1,4 | 1,4 | 1,4 | 2,5 | 2,5 |
capacity | L | 5,5 | 6,5 | 6,5 | 6,5 | 15 | 15 |
pressure drop (2 m³/h) | mbar | 42 | 83 | 83 | 83 | 123 | 123 |
max. operating pressure | bar | 10 | 10 | 10 | 10 | 10 | 10 |
max. operating temperature | °C | 95 | 95 | 95 | 95 | 95 | 95 |
tap power output heat exchanger top | 200 | 300 | 400 | 500 | 750 | 1000 | |
continuous tap output at 17 kW (Tflow 70°C), CW 10°C/HW 45°C | L/h | 351 | 617 | 662 | 702 | 813 | 869 |
Zapfleistung bei 27 kW (Tflow 70°C), CW 10°C/HW 45°C | L/h | 490 | 890 | 935 | 975 | 1090 | 1145 |
Zapfleistung bei 50 kW (Tflow 70°C), CW 10°C/HW 45°C | L/h | 788 | 1495 | 1535 | 1580 | 1690 | 1745 |
performance indicator NL at 70/50 heat exchanger top | NL | 2,4 | 3,1 | 3,6 | 4,8 | 11,6 | 16,8 |
performance indicator NL at 70/50 both heat exchangers | NL | 5,6 | 7,2 | 11,4 | 13,7 | 26,5 | 34,2 |
specification solar heat exchanger bottom | 200 | 300 | 400 | 500 | 750 | 1000 | |
heating surface | m² | 0,9 | 1,8 | 2,2 | 2,4 | 2,5 | 2,5 |
capacity | L | 5,5 | 8,3 | 10,5 | 13,5 | 15 | 15 |
pressure drop (2 m³/h) | mbar | 43 | 98 | 109 | 135 | 136 | 136 |
max. operating pressure | bar | 10 | 10 | 10 | 10 | 10 | 10 |
max. operating temperature | °C | 110 | 110 | 110 | 110 | 110 | 110 |
recommended min. collector surface | m² | 4 | 6 | 8 | 10 | 14 | 17 |
connections with dimensioning | 200 | 300 | 400 | 500 | 750 | 1000 | |
[1] anode (from SKL 400 on an additional anode in the flange) | oben (1¼“) |
oben (1¼“) |
oben (1¼“) |
oben (1¼“) |
oben (1¼“) |
oben (1¼“) |
|
[2] hot water | mm |
1165 (1“IG) |
1345 (¾“IG) |
1505 (¾“IG) |
1640 (¾“IG) |
1590 (1¼“IG) |
1840 (1¼“IG) |
[3] heating flow (inlet) | mm |
995 (1¼“IG) |
1245 (1“IG) |
1355 (1“IG) |
1510 (1“IG) |
1440 (1¼“IG) |
1440 (1¼“IG) |
[4] thermometer | mm |
930 (½“IG) |
1200 (½“IG) |
1300 (18x2) |
1450 (18x2) |
1460 (½“IG) |
1680 (½“IG) |
[5] tap water sensor | mm |
915 (½“IG) |
1080 (½“IG) |
1125 (½“IG) |
1285 (½“IG) |
1340 (½“IG) |
1340 (½“IG) |
[6] circulation | mm |
885 (¾“IG) |
985 (¾“IG) |
1030 (¾“IG) |
1185 (¾“IG) |
1235 (1“IG) |
1235 (1“IG) |
[7] heating return (outlet) | mm |
680 (1¼“IG) |
885 (1“IG) |
935 (1“IG) |
1060 (1“IG) |
990 (1¼“IG) |
990 (1¼“IG) |
[8] electric heating element | mm |
630 (1½“IG) |
830 (1½“IG) |
880 (1½“IG) |
1010 (1½“IG) |
890 (1½“IG) |
890 (1½“IG) |
[9] solar flow (inlet) | mm |
580 (1¼“IG) |
770 (¾“IG) |
805 (¾“IG) |
885 (¾“IG) |
835 (1¼“IG) |
835 (1¼“IG) |
[10] solar sensor | mm |
475 (½“IG) |
400 (½“IG) |
420 (½“IG) |
370 (½“IG) |
685 (½“IG) |
685 (½“IG) |
[11] flange Ø 114 mm (from SKL 400 on with addidional anode) | mm |
260 - |
400 - |
420 (M8x30) |
390 (M8x30) |
400 (M8x30) |
400 (M8x30) |
[12] solar return (outlet) | mm |
265 (1¼“IG) |
245 (1“IG) |
265 (1“IG) |
285 (1“IG) |
385 (1¼“IG) |
385 (1¼“IG) |
[13] cold water | mm |
70 (1“IG) |
145 (¾“IG) |
110 (¾“IG) |
165 (¾“IG) |
220 (1¼“IG) |
220 (1¼“IG) |
SKL Typ 300, 400 und 500
SKL Typ 200, 750 und 1000
Manufacturing tolerance according to DIN ISO 13920 C
Please take the instructions for installation/start up/maintenance from the relevant operation manuals