Wood gasification boiler BioX
( 5 products )Solarbayer BioX wood gasification boilers are perfect for combustion of natural, split logs with 0.5 m log length, with lowest emission values and high energy efficiency, available in sizes BioX 15, BioX 20 (filling volume 125 L) or BioX 25, BioX 35, BioX 45 (filling volume 185 L), optionally available with BioX design front door, fully automatic heat exchanger cleaning and stainless steel combustion chamber.
Why choose the Solarbayer BioX wood log boiler?
BioX is the result of Solarbayers’ many years of experience in the development, production and distribution
of wood log gasification boilers.
The BioX wood log boiler not only convinces optically.
The separation of the heating, filling and combustion chamber doors allows a comfortable heating up and reloading.
The large filling chamber enables a long burnoff period with minimum effort.
An integrated flue gas outlet prevents the generation of flue gas in the boiler room and offers a smokefree
reloading of the boiler.
The cleaning of the BioX is very userfriendly due to its semirespectively fully automatic heat exchanger cleaning (optionally available).
The extremely low amount of ash can easily be removed through the ash door.
Convincing technology
The double hightemperature cyclone combustion chamber and the used silicone carbide (SiC) that acts like a catalyst,
provide for a particularly efficient and clean combustion process with very high efficiency and minimum emissions.
The nitrogen oxide output is extremly low and the respirable dust pollution is hardly measurable.
With its emissions it is far below the maximum permissible values specified by the German Federal Immission Control
Ordinance (1.BImschV, level 2).
By using highquality and very robust components (e.g. combustion chamber bricks made of SiC)
the BioX offers an extremely long service life with minimum followup costs.
The wood gasification boiler BioX from Solarbayer is exemplary environmentally friendly and economical.
Brief description
- Wood log gasification boiler for central heating with upper wood gasification and lower burnoff
- solid boiler construction according to German quality standard
- easy and comfortable heating
- the large fuel chamber guarantees a long burning period
- innovative wood boiler technology
- turbulators for more performance and lower exhaust gas tempartures
- either semiautomatic or fully automatic heat exchanger cleaning
- easy handling and cleaning, low amount of ashes
- Extremely fireresistant combustion chamber made of silicon carbide (SiC)
- additional comfort-heating-door
- heating up and reloading possible without the use of the controller due to intelligent door contact switch
- solid lifting eye for easy insertion to basement boiler rooms
- modulation combustion, exhaust gas and lambda control ensure the compliance of the currently valid limit values of the Federal Immission Control Ordinance
- boiler sizes from 15 kW to 45 kW
- log length 50 cm
- door hinge changeable from right-hinged to left-hinged
BioX 15 | BioX 20 | BioX 25 | BioX 35 | BioX 45 | |
Lambda sensor | • | • | • | • | • |
induced draft fan | • | • | • | • | • |
front door | (Aufpreis) | (Aufpreis) | (Aufpreis) | (Aufpreis) | (Aufpreis) |
half automatic heat exchanger cleaning | • | • | • | • | • |
fully automatic heat exchanger cleaning | (Aufpreis) | (Aufpreis) | (Aufpreis) | (Aufpreis) | (Aufpreis) |
Stainless steel fuel chamber lining | (Aufpreis) | (Aufpreis) | (Aufpreis) | (Aufpreis) | (Aufpreis) |
Cleaning tools | • | • | • | • | • |
1. BImSchV*, level 2:
currently valid for all wood log boilers in Germany (installed after 01.01.2017)
All Solarbayer wood log boilers BioX meet the austere limit values of the Federal Immission Control Ordinance
*First Decree of the Implementation of the Federal Immission Control Ordinance (Ordinance on small and medium combustion plants – 1. BImSchV)
Heating with wood
Convincing details
Discover the details
For more information on the details, please click on the numbered markers in the cutaway image.
Variants
/\
Stainless steel fuel chamber lining (optional)
The optional hinged stainless steel
plates take care of a decreased tar
formation in the fuel chamber and
protects the walls from severe hits.
Two integrated stainless steel air
distribution plates in the bottom are
standard.
/\
Fully automatic heat exchanger cleaning (optional)
No more dirty hands: A fully automatic
heat exchanger cleaning takes care of the
cleaning each time the fuel chamber door
is opened and at regularly intervals.
Clean heat exchanger tubes
guarantee a better efficiency factor and
lower emissions.
/\
Left/Right hinged boiler doors
All doors come right-hinged, which
means they open up to the right side.
If it would be more handy to do it the otherway
round, because for example
space is limited in the boiler room, then
the doors can easily be turned by 180°
due to the clever design and mounted on
the other side.
Example of Solarbayer BioX wood gasifier heating
Systems that work - Solarbayer wood gasification boiler sets BioX
The combination of appropriate components is essential for the total efficiency of a wood boiler system!
Solarbayer wood log boiler sets are generelly equipped with patented Solarbayer stratification storage tanks SLS®.
This guarantees an immediate and very efficient heat supply to the heating system even at cold buffer temperatures when the boiler is started.
Due to the large filling chamber of BioX boilers Solarbayer recommends a minimum storage tank capacity of approx. 12 ltr. each 1 ltr. filling chamber room, to optimize the efficiency of the boiler.
Regardless, legal regulations and requirements for subsidies of course have to be respected.
incl. fire protection insulation ISOB1®
(difficult to ignite)
The single components in each set can be changed according to your needs. Our technicians will be glad to advise you.
Boiler dimensions
Technical specifications
Dimension and weight | type | BioX 15 | BioX 20 | BioX 25 | BioX 35 | BioX 45 |
length complete A | mm | 1255 | 1255 | 1339 | 1339 | 1339 |
length covering A1 | mm | 1021 | 1021 | 1021 | 1021 | 1021 |
length up to end of flue spigot A2 | mm | 1179 | 1179 | 1194 | 1194 | 1194 |
width (without covering) B | mm | 610 (605) | 610 (605) | 670 (665) | 670 (665) | 670 (665) |
height (without covering) C | mm | 1365 (1350) | 1365 (1350) | 1585 (1576) | 1585 (1576) | 1585 (1576) |
flue spigot D | mm | 150 | 150 | 150 | 150 | 150 |
fuel chamber height E | mm | 260 | 260 | 305 | 305 | 305 |
fuel chamber width F | mm | 400 | 400 | 460 | 460 | 460 |
flue spigot top edge G | mm | 1225 | 1225 | 1494 | 1494 | 1494 |
flue spigot middle (G) | mm | 1050 | 1050 | 1275 | 1275 | 1275 |
height boiler flow line H | mm | 1155 | 1155 | 1380 | 1380 | 1380 |
height boiler return line I | mm | 240 | 240 | 240 | 240 | 240 |
minimum distance back side J | mm | 600 | 600 | 600 | 600 | 600 |
minimum distance front side K | mm | 520 | 520 | 600 | 600 | 600 |
height draining L | mm | 135 | 135 | 135 | 135 | 135 |
required mimimun room height | mm | 1700 | 1700 | 1920 | 1920 | 1920 |
connection boiler flow/return 1 + 2 | Ø | 1" (IG) DN 25 |
1" (IG) DN 25 |
1 ¼" (IG) DN 32 |
1 ¼" (IG) DN 32 |
1 ¼" (IG) DN 32 |
connection safety heat exchanger 3 | Ø | ½" (IG) DN 15 |
½" (IG) DN 15 |
½" (IG) DN 15 |
½" (IG) DN 15 |
½" (IG) DN 15 |
connection draining 4 | Ø | ½" (IG) DN 15 |
½" (IG) DN 15 |
½" (IG) DN 15 |
½" (IG) DN 15 |
½" (IG) DN 15 |
boiler weight | kg | 461 | 461 | 564 | 564 | 564 |
fuel chamber/fuel consumption | type | BioX 15 | BioX 20 | BioX 25 | BioX 35 | BioX 45 |
admissible fuel | ntreated, split wood log with residual moisture <20% | |||||
max. wood log length | mm | 550 | 550 | 550 | 550 | 550 |
fuel chamber depth | mm | 590 | 590 | 590 | 590 | 590 |
fuel chamber height | mm | 525 | 525 | 665 | 665 | 665 |
fuel chamber width | mm | 400 | 400 | 460 | 460 | 460 |
dimension of the filling hole w/h | mm | 400/260 | 400/260 | 460/305 | 460/305 | 460/305 |
fuel chamber capacity, volume litre approx. | L | 125 | 125 | 185 | 185 | 185 |
max. filling weight (beech) approx. | kg | 40 | 40 | 54 | 54 | 54 |
fuel consumption at rated power (beech) approx. | kg/h | 5 | 6.7 | 6.8 | 7.7 | 7.5 |
combustion period at nominal load (beech) approx. | h | 6 | 5 | 7 | 6 | 4.5 |
Exhaust gas routing | type | BioX 15 | BioX 20 | BioX 25 | BioX 35 | BioX 45 |
recommended min. chimney cross section | mm | 150 | 150 | 150 | 150 | 150 |
draft requirements | Pa | -10...-15 | -10...-15 | -10...-15 | -10...-15 | -10...-15 |
effective minimum chimney height | m | 7 | 7 | 7 | 7 | 7 |
exhaust gas mass flow | g/s | 9.8 | 12.2 | 15.2 | 21.2 | 27.2 |
modulating exhaust gas temperature | °C | 180 | 220 | 180 | 200 | 240 |
recommended exhaust piping length | developed length < 1,5m (max. 2 curves) | |||||
barometic damper | definitely recommended |
Electrical data | type | BioX 15 | BioX 20 | BioX 25 | BioX 35 | BioX 45 |
mains voltage / frequency | V/Hz | ~230/50 | ~230/50 | ~230/50 | ~230/50 | ~230/50 |
power consumption standby | W | < 0.3 | < 0.3 | < 0.3 | < 0.3 | < 0.3 |
power consumption operation | W | 90 | 90 | 150 | 150 | 150 |
Hydraulic | type | BioX 15 | BioX 20 | BioX 25 | BioX 35 | BioX 45 |
recommended min. buffer tank volume 1) | L | 1000 | 1500 | 2000 | 2000 | 2500 |
manufacturer's recommendation 1) | L | 1500 | 2000 | 2500 | 2500 | 3000 |
min. tube dimension (CU-/steel precision tube) Ø 2) | Ø mm | 28 | 28 | 35 | 35 | 35 |
min. tube dimension (steel tube) 2) | Ø | 1" DN 25 |
1" DN 25 |
1 ¼" DN 32 |
1 ¼" DN 32 |
1 ½" DN 32 |
preset min. bioler return line temperature for the Solarbayer boiler charging unit (controlled by boiler control unit) | °C | 70 | 70 | 70 | 68 | 66 |
1 Legal regulations and requirements for subsidies have to be respected
2 Needs to be dimsioned larger depending on pipe length, number of bends, mixing valves, changeover valvex, etc. The here stated pipe dimensions are only a recommendation and to not replace professional technical planning.
Attention:
If the optional available boiler front door is mounted the total length of the boiler is elongated about 6mm. With the optional available stainless steel fuel chamber cladding the fuel chamber capacity is slightly reduced.
rotatable exhaust gas connection resp. fan (ca. 0° - 135°)
Video about heating up a wood gasification boiler Solarbayer BioX
Intro:
Track: Robin Hustin - On Fire [NCS Release]
Music provided by NoCopyrightSounds.
Watch: https://youtu.be/S0STHSOPPSM
Free Download / Stream: http://ncs.io/OnFireYO
Outro:
Track: Jim Yosef - Lights [NCS Release]
Music provided by NoCopyrightSounds.
Watch: https://youtu.be/vb3ks4WllXA
Free Download / Stream: https://ncs.io/lights