Hot water loading tank BW-0
( 10 products )enameled tank, 0 heat exchanger
(Artikelnummer: 100400000)
Item no. 100400000
enameled tank, 0 heat exchanger
(Artikelnummer: 100400100)
Item no. 100400100
enameled tank, 0 heat exchanger
(Artikelnummer: 100400200)
Item no. 100400200
enameled tank, 0 heat exchanger
(Artikelnummer: 100400300)
Item no. 100400300
enameled tank, 0 heat exchanger
(Artikelnummer: 100400400)
Item no. 100400400
enameled tank, 0 heat exchanger
(Artikelnummer: 100400500)
Item no. 100400500
enameled tank, 0 heat exchanger
(Artikelnummer: 100400600)
Item no. 100400600
enameled tank, 0 heat exchanger
(Artikelnummer: 100400700)
Item no. 100400700
enameled tank, 0 heat exchanger
(Artikelnummer: 100400800)
Item no. 100400800
enameled Solar DHW tank, 2 heat exchanger
(Artikelnummer: 100402100)
Item no. 100402100
Find more products in the categories
Warmwasser-Ladespeicher BW-0
Warmwasserspeicher für präzise Beladung durch externe Wärmetauscher
Der Warmwasser-Ladespeicher BW-0 ohne integrierten Wärmetauscher ist die richtige Wahl, wenn die Erwärmung
über einen außenliegenden Wärmetauscher erfolgt. Er eignet sich sowohl für private Haushalte als auch für
gewerbliche und industrielle Anwendungen. Mit Hilfe eines externen Wärmetauschers kann das gesamte Speichervolumen
effizient und gleichmäßig von oben nach unten auf die Solltemperatur aufgeheizt werden. Dadurch wird
die Nutztemperatur schnell erreicht, die Aufheizzeit verkürzt und gleichzeitig Energie gespart. Der seitliche Warmwasseraustritt
verhindert unerwünschte Zirkulation und reduziert die Bereitschaftsverluste. Kalt- und Mischzonen
werden auf ein Minimum reduziert, so dass immer Warmwasser in der gewünschten Temperatur zur Verfügung steht.
Die universellen Anschlüsse ermöglichen den flexiblen Einsatz als Ladespeicher oder hydraulische Weiche. Zusätzlich kann auch
ein elektrischer Heizstab integriert werden. Zur Erhöhung der Warmwasserleistung können diese Ladespeicher auch in Reihe
geschaltet werden. Diese Anordnung gewährleistet neben einer einfachen Verrohrung eine gleichmäßige Warmwassertemperatur
in allen Speichern sowie eine konstante Zapftemperatur. Die langlebige Zweischicht-Emaillierung, geschützt durch Magnesium-
Schutzanoden garantiert eine hohe Beständigkeit und sorgt für eine lange Lebensdauer. Zudem erleichtert ein integrierter
Reinigungsflansch die Wartungs- und Inspektionsarbeiten. Ob für private, gewerbliche oder industrielle Anwendungen – dieser
Ladespeicher überzeugt durch hohe Effizienz, schnelles Aufheizen, geringen Energieverlust und flexible Einsatzmöglichkeiten.
Eine zuverlässige und langlebige Lösung für die Warmwasserversorgung!
Was sind die Vorteile der Warmwasser-Ladespeicher BW-0 von Solarbayer?
- Warmwasserspeicher für die Aufheizung durch externe Wärmetauscher
- lange Lebensdauer durch hochbeständige Emaillierung und Schutzanode
- Zirkulationsanschluss
- Anschlussmuffe für einen Elektroheizstab vorhanden
- Magnesium-Schutzanoden in passender Größe vormontiert
- Erhöhung der Warmwasserleistung bei Serienschaltung
- Reinigungsöffnung, optional mit zusätzlicher Anschlussmuffe für E-Heizstab
- Brandschutzklasse der Wärmedämmung: B2
- hochwertige PU-Hartschaumdämmung, ab 1.500 Liter mit Vlies-Dämmung
- Große Auswahl an Speichergrößen (200 bis 3000 Liter)
Technische Daten
| Warmwasser-Ladespeicher BW-0 | 200 | 300 | 400 | 500 | 750 | 1000 | 1500 | 2000 | 3000 | ||
| Artikelnummer | 100400000 | 100400100 | 100400200 | 100400300 | 100400400 | 100400500 | 100400600 | 100400700 | 100400800 | ||
| Nennvolumen | L | 216 | 312 | 424 | 512 | 762 | 882 | 1488 | 2007 | 2823 | |
| Korrosionsschutz | Emaillierung, inkl. Magnesiumanode | ||||||||||
| Gewicht | kg | 61 | 80 | 96 | 108 | 173 | 194 | 322 | 396 | 579 | |
| Höhe mit Dämmung | [A] | mm | 1285 | 1730 | 1715 | 1805 | 1845 | 2095 | 2285 | 2550 | 2980 |
| Höhe ohne Dämmung | [B] | mm | - | - | - | - | 1790 | 2040 | 2205 | 2470 | 2900 |
| Kippmaß | mm | 1475 | 1880 | 1905 | 2000 | 1890 | 2115 | 2325 | 2595 | 3010 | |
| Durchmesser mit Dämmung | [C] | mm | 655 | 655 | 755 | 790 | 950 | 950 | 1200 | 1300 | 1400 |
| Durchmesser ohne Dämmung | [D] | mm | - | - | - | - | 790 | 790 | 1000 | 1100 | 1200 |
| max. Einbaulänge Elektroheizstab | mm | 520 | 520 | 620 | 670 | 810 | 810 | 1020 | 1120 | 1220 | |
| Dämmung PU Hartschaum (fest aufgeschäumt) | mm | 75 | 75 | 75 | 70 | - | - | - | - | - | |
| Dämmung PU Hartschaum (abnehmbar) | mm | - | - | - | - | 80 | 80 | - | - | - | |
| Vlies-Dämmung (abnehmbar) | mm | - | - | - | - | - | - | 100 | 100 | 100 | |
| Außenmantel | PVC, Farbe Silber | ||||||||||
| Bereitschaftswärmeaufwand 1 | kWh/24h | 1,16 | 1,45 | 1,64 | 1,82 | 2,76 | 2,99 | 3,73 | 4,40 | 7,33 | |
| Warmhalteverlust 1 | W | 48 | 60 | 68 | 76 | 115 | 125 | 155 | 183 | 305 | |
| Energieeffizienzklasse 1 | B | B | B | B | C | C | C | C | - | ||
| max. Betriebsdruck | bar | 10 | |||||||||
| max. Betriebstemperatur | °C | 95 | |||||||||
| Anschlüsse mit Bemaßung | 200 | 300 | 400 | 500 | 750 | 1000 | 1500 | 2000 | 3000 | ||
| [1] Anode (oben) | 1 ¼" IG | mm | L: 400 | L: 400 | L: 500 | L: 500 | L: 650 | L: 750 | L: 650 | L: 900 | L: 900 |
| [2] Warmwasser | 1 ½" IG | mm | 1120 | 1565 | 1540 | 1595 | 1590 | 1840 (2" IG) | 1935 (2" IG) | 2210 (2" IG) | 2550 (2" IG) |
| [3] Thermometer | ½" IG | mm | 929 | 1384 | 1411 | 1480 | 1460 | 1680 | 1825 | 2090 | 2430 |
| [4] Freier Anschluss | 1 ¼" IG | mm | 994 | 1294 | 1361 | 1335 | 1440 | 1440 | 1735 | 2000 | 2340 |
| [5] Fühler | ½" IG | mm | 914 | 1214 | 1245 | 1285 | 1340 | 1340 | 1600 | 1825 | 2205 |
| [6] Zirkulation | 1" IG | mm | 884 (¾" IG) | 1141 (¾" IG) | 1163 (¾" IG) | 1235 | 1235 | 1235 | 1460 | 1650 | 2040 |
| [7] Freier Anschluss | 1 ¼" IG | mm | 679 | 979 | 1011 | 985 | 990 | 990 | 1330 | 1450 | 1790 |
| [8] Freier Anschluss | 1 ¼" IG | mm | 579 | 849 | 846 | 865 | 835 | 835 | 1180 | 1160 | 1300 |
| [9] Elektroheizstab | 1 ½" IG | mm | 629 | 914 | 891 | 949 | 890 | 890 | 1255 | 1310 | 1400 |
| [10] Fühler | ½" IG | mm | 474 | 654 | 660 | 685 | 685 | 685 | 945 | 985 | 1075 |
| [11] Flansch (ab 1500 L mit Anode M8x30) 2 | mm | 257 | 257 | 268 | 335 | 400 | 400 | 520 (L: 400) | 550 (L: 400) | 640 (L: 750) | |
| [12] Freier Anschluss | 1 ¼" IG | mm | 264 | 264 | 286 | 305 | 385 | 385 | 470 | 460 | 550 |
| [13] Kaltwasser | 1" ½ IG | mm | 110 | 110 | 120 | 175 | 220 | 220 (2" IG) | 315 (2" IG) | 340 (2" IG) | 430 (2" IG) |
Fertigungstoleranzen nach DIN EN ISO 13920 C
Hinweise zu Montage/Inbetriebnahme/Wartung entnehmen Sie bitte der entsprechenden Anleitung
1 Bereitschaftswärmeaufwand nach DIN EN 12897
2 Außen = 170 mm; Lochkreis = 145mm; 8-Loch (M10)
Speicherbemaßung
Anschlussbeispiel
Hydraulikbeispiel
FAQ - Häufig gestellte Fragen
Wo werden emaillierte Warmwasserspeicher eingesetzt?
Emaillierte Warmwasserspeicher dienen der Bevorratung des benötigten Warmwassers in Form von gespeicherter Energie im Trinkwarmwasserspeicher oder als Brauchwassertank. Meist werden sie in Heizungsanlagen mit zentraler Trinkwarmwasserversorgung für eine sichere Warmwasserbereitung verwendet und bieten durch die Vorratsspeicherung einen sehr hohen Warmwasserkomfort. Da sie sehr universell aufgebaut sind können diese Speicher praktisch fast überall eingesetzt werden.
Warum benötigt man die Opferanode?
Trotz der hochwertigen Doppel-Emaillierung der Speicher von Solarbayer im Zweischichtverfahren können Schwachstellen an der Emaillierung nie zu hundert Prozent ausgeschlossen werden. Deshalb ist ein zusätzlicher Korrosionsschutz immer unbedingt erforderlich, bspw. mittels der serienmäßig eingebauten Opferanode (Magnesiumstabanode). Im Falle, das es eine Schwachstelle in der Emaillierung gibt, schützt ein elektrochemischer Prozess den Speicher. Sobald das Wasser im Speicher die Verbindung zum Stahl hergestellt hat, beginnt das Magnesium sich aufzulösen, und die Partikel wandern zu der Fehlstelle, wo sie eine schützende Schicht herstellen und so eine Korrosion verhindern.
Wie oft muss eine Opferanode gewechselt werden?
Wie häufig eine Opferanode erneuert werden muss hängt von der Qualität der Emailliebeschichtung ab.
Da Solarbayer Speicher eine sehr hochwertige Emaillierung besitzen, kann eine Magnesiumstabanode viele Jahre arbeiten.
Nichtsdestotrotz ist eine regelmäßige Kontrolle unerlässlich, wir empfehlen die Anodenprüfung mindestens einmal jährlich durchzuführen.
Zur Überprüfung genügt eine Sichtkontrolle. Hierzu wird die Wasserzufuhr zum Speicher abgestellt, danach kann die Anode oben herausgeschraubt
und ein Stück weit nach oben herausgezogen werden. Hat sich die Anode zu mehr als zwei Drittel aufgelöst, muss sie erneuert werden.
Alternativ kann zur Kontrolle auch ein Anodenprüfgerät verwendet werden.
Optional zur Magnesiumanode haben sich auch Fremdstromanoden bewährt, welche den Wartungsaufwand deutlich verringern
und ebenfalls einen optimalen Speicherschutz bieten.
Wie hoch ist die Legionellengefahr in Warmwasserspeichern?
Vorab: grundsätzlich ist hier die Einhaltung der Trinkwasserverordnung zu beachten. An dieser Stelle geben wir Ihnen eine Kurzinformation mit den wichtigsten Fakten zu diesem Thema. Legionellen im Leitungswasser sind bei geringen Vorkommen unbedenklich. Wenn sich die Legionellen vermehren, können Sie jedoch beim Einatmen (bspw. beim Duschvorgang) Fieber, in schweren Fällen auch eine Pneumonie (Lungenentzündung) hervorrufen. Daher ist es wichtig, eine Vermehrung zu verhindern (Legionellenschutz). Da sich die Legionellen am schnellsten bei Wassertemperaturen zwischen 30°C bis 50°C vermehren, gilt es, den Speicher Konstant auf 50°C oder höher zu erwärmen. Bei Temperaturen über 50°C ist die Vermehrung nur noch sehr langsam, bei Temperaturen ab 60°C wird die Vermehrung gestoppt. Wird der Speicher auf bis zu 70°C erwärmt, ist der Speicher frei von Legionellen (thermische Desinfektion). Gerade für Heizungsanlagen mit Biomassekesseln oder in den Sommer- und Übergangsmonaten in Kombination mit Solarthermie ist es recht einfach, die Speichertemperatur konstant auf 60°C oder höher zu erhalten, und somit einen sicheren Legionellenschutz zu erreichen. In vermieteten Mehrfamilienhäusern oder in Großanlagen mit mehreren Duschstellen gibt es zudem eine Überprüfungspflicht, welche durch die Trinkwasserverordnung geregelt wird. Auch das DVGW-Arbeitsblatt W 551 und die 3-Liter-Regel definieren die Vorgaben für den Bau von Trinkwasser-Installationen und die Einhaltung der Legionellensicherheit.