Accessories
( 11 products )with high-efficiency pump
(Artikelnummer: 130000100)
Item no. 130000100
with nonstick coating
(Artikelnummer: 130030700)
Item no. 130030700
Accumulators insulation up to 500 litres
(Artikelnummer: 130041500)
Item no. 130041500
8-hole distance 145mm
(Artikelnummer: 130050200)
Item no. 130050200
Outside 160mm, 8-holes, bolt circle 145mm
(Artikelnummer: 130050400)
Item no. 130050400
WP 200-500 WP-S and SKL200/750/1000
(Artikelnummer: 130300000)
Item no. 130300000
WP - H series 300-600 liters
(Artikelnummer: 130302000)
Item no. 130302000
for SKL and WP boilers
(Artikelnummer: 190500000)
Item no. 190500000
for SKL and WP boilers
(Artikelnummer: 190500101)
Item no. 190500101
for enameled DHW tanks
(Artikelnummer: 190500200)
Item no. 190500200
incl. rotatable pressure reducer
(Artikelnummer: 540310100)
Item no. 540310100
Wärmepumpen Warmwasserspeicher WP
Emaillierter Hochleistungs-Warmwasserspeicher mit einem großflächigen Wärmetauscher zur zentralen Warmwasserversorgung, ideal für Wärmepumpen
Der emaillierte monovalente Wärmepumpen-Warmwasserspeicher WP ist die ideale Lösung für alle, die ihre
Warmwasserbereitung effi zienter und komfortabler gestalten möchten. Der innovative parallel gewickelt und
angeschlossene Doppelregister-Wärmetauscher minimiert den Druckverlust deutlich und ermöglicht eine außergewöhnliche
Wärmeübertragung. Die große Oberfl äche des Wärmetauschers spielt eine entscheidende Rolle für
die Effi zienz und Leistung bei einer Wärmepumpe oder einem Brennwert-Wärmeerzeuger. Dieser Hochleistungs-
Warmwasserspeicher ist auch mit anderen Wärmeerzeugern kombinierbar, sodass Sie später jederzeit die Option
haben, eine Wärmepumpe zu ergänzen oder den bestehenden Wärmeerzeuger durch eine Wärmepumpe zu ersetzen.
Damit sind Sie bereits heute für zukünftige Anforderungen bestens gerüstet. Die langlebige hochwertige Emaillierung,
geschützt durch Magnesium-Schutzanoden, garantiert eine hohe Beständigkeit.
Der Speicher verfügt über einen Reinigungsfl ansch, einen Zirkulationsanschluss, ein Thermometer sowie einen Fühleranschluss.
Zudem ist ein Anschluss für einen Elektroheizstab als Notheizung oder zur Nutzung von überschüssigem PV-Strom vorhanden.
Im Flansch kann ein zusätzlicher Heizstab installiert werden, hierzu ist eine optionale Flanschplatte als Zubehör erhältlich.
Die extrastarke Dämmung sorgt für erstklassige Wärmedämmung und minimiert Wärmeverluste auf ein Minimum.
Was sind die Vorteile der Wärmepumpen Warmwasserspeicher WP von Solarbayer?
- Wärmepumpen-Warmwasserspeicher für den monovalenten Betrieb
- sehr großer doppelt gewickelter Hochleistungswärmetauscher
- minimaler Druckverlust des Wärmetauschers, da parallel durchströmt
- auch mit anderen Wärmeerzeugern kompatibel für eine spätere Umrüstung
- lange Lebensdauer durch hochbeständige Emaillierung und Magnesium-Schutzanode
- Zirkulationsanschluss
- Reinigungsöffnung, optional mit zusätzlicher Anschlussmuffe für E-Heizstab
- Brandschutzklasse der Wärmedämmung: B2
- hochwertige PU-Hartschaumdämmung (ab 750 Liter abnehmbar), ab 1.500 Liter mit Vlies-Dämmung
- Speichergrößen von 200 bis 2.000 Liter
Technische Daten
| Wärmepumpen-Warmwasserspeicher WP | 200 | 300 | 400 | 500 | 750 | 1000 | 1500 | 2000 | ||
| Artikelnummer | 100301000 | 100301100 | 100301200 | 100301300 | 100301400 | 100301500 | 100301600 | 100301700 | ||
| Nennvolumen | L | 203 | 287 | 395 | 470 | 741 | 857 | 1484 | 1860 | |
| Korrosionsschutz | Emaillierung, inkl. Magnesiumanode | |||||||||
| Gewicht | kg | 115 | 145 | 180 | 220 | 292 | 360 | 495 | 530 | |
| Höhe ohne Dämmung | [A] | mm | - | - | - | - | 1790 | 2040 | 2205 | 2470 |
| Höhe mit Dämmung | [B] | mm | 1290 | 1730 | 1670 | 1810 | 1865 | 2110 | 2285 | 2595 |
| Kippmaß | mm | 1441 | 1849 | 1836 | 1971 | 1890 | 2115 | 2325 | 2520 | |
| Durchmesser ohne Dämmung | [C] | mm | - | - | - | - | 790 | 790 | 1000 | 1100 |
| Durchmesser mit Dämmung | [D] | mm | 650 | 650 | 750 | 790 | 950 | 950 | 1200 | 1300 |
| max. Einbaulänge Elektroheizstab | mm | 550 | 550 | 650 | 700 | 790 | - | - | - | |
| Dämmstärke mit Außenmantel | [E] | mm | 75 | 75 | 75 | 70 | 80 | 80 | 100 | 100 |
| Dämmung + Außenmantel | PUR Hartschaum, fest geschäumt + PVC, Farbe Silber | |||||||||
| Bereitschaftswärmeaufwand 1 | kWh/24h | 1,03 | 1,31 | 1,49 | 1,66 | 2,54 | 2,95 | 3,46 | 4,13 | |
| Warmhalteverlust 1 | W | 43 | 55 | 62 | 69 | 106 | 123 | 144 | 172 | |
| Energieeffizienzklasse 1 | A | B | B | B | C | C | C | C | ||
| max. Betriebsdruck | bar | 10 | ||||||||
| max. Betriebstemperatur | °C | 95 | ||||||||
| Daten Wärmetauscher | 200 | 300 | 400 | 500 | 750 | 1000 | 1500 | 2000 | ||
| Heizfläche Doppelregister | m² | 3 | 3,8 | 5 | 5,9 | 7,5 | 10 | 11 | 12 | |
| Inhalt | L | 18,5 | 23,1 | 30 | 36,3 | 46,2 | 63 | 70 | 73 | |
| max. Betriebsdruck | bar | 10 | ||||||||
| max. Betriebstemperatur | °C | 110 | ||||||||
| Anschlüsse mit Bemaßung | 200 | 300 | 400 | 500 | 750 | 1000 | 1500 | 2000 | ||
| [1] Anode (oben) | 1 ¼" IG | mm | L: 650 | L: 900 | L: 750 | L: 900 | L: 400 | |||
| [2] Anode (oben) | 1 ¼" IG | mm | - | |||||||
| [3] Warmwasser | 1" IG | mm | 1164 | 1609 | 1541 | 1595 (1 ¼) | 1590 (1 ¼) | 1840 (1 ¼) | 1935 (2") | 2210 (2") |
| [4] Thermometer | ½" IG | mm | 1040 | 1430 | 1385 | 1475 | 1450 | 1730 | 1825 | 2090 |
| [5] Zirkulation | ¾" IG | mm | 990 | 1200 | 1205 | 1375 (1") | 1140 (1") | 1235 (1") | 1460 (1 ¼") | 1795 (1 ¼") |
| [6] Elektroheizstab | 1 ½" IG | mm | 940 | 1150 | 1165 | 1335 | 1300 | - | - | - |
| [7] Vorlauf Heizung | 1 ¼" IG | mm | 890 | 1080 | 1100 | 1235 | 1250 (1 ½") | 1695 (1 ½") | 1620 (1 ½") | 1655 (1 ½") |
| [8] Sensor | ½" IG | mm | 593 | 653 | 690 | 825 | 775 | 1193 | 1260 | 1295 |
| [9] Sensor | ½" IG | mm | - | - | - | - | - | 542 | 870 | 905 |
| [10] Flansch (ab 400 L mit Anode M8x30)2 | mm | 257 | 270 | 280 (L: 400) | 360 (L: 400) | 400 (L: 400) | 400 (L: 400) | 530 (L: 650) | 565 (L: 900) | |
| [11] Rücklauf Heizung | 1 ¼" IG | mm | 210 | 230 | 250 | 295 | 370 (1 ½") | 345 (1 ½") | 450 (1 ½") | 485 (1 ½") |
| [12] Kaltwasser | 1" IG | mm | 67 | 67 | 79 | 175 (1 ¼") | 220 (1 ¼") | 220 (1 ¼") | 315 (2") | 340 (2") |
Fertigungstoleranzen nach DIN EN ISO 13920 C
Hinweise zu Montage/Inbetriebnahme/Wartung entnehmen Sie bitte der entsprechenden Anleitung
1 Bereitschaftswärmeaufwand nach DIN EN 12897
2 Außen = 170 mm; Lochkreis = 145mm; 8-Loch (M10)
Speicherbemaßung
Anschlussbeispiel
Hydraulikbeispiel
FAQ - Häufig gestellte Fragen
Wo werden emaillierte Warmwasserspeicher eingesetzt?
Emaillierte Warmwasserspeicher dienen der Bevorratung des benötigten Warmwassers in Form von gespeicherter Energie im Trinkwarmwasserspeicher oder als Brauchwassertank. Meist werden sie in Heizungsanlagen mit zentraler Trinkwarmwasserversorgung für eine sichere Warmwasserbereitung verwendet und bieten durch die Vorratsspeicherung einen sehr hohen Warmwasserkomfort. Da sie sehr universell aufgebaut sind können diese Speicher praktisch fast überall eingesetzt werden.
Warum benötigt man die Opferanode?
Trotz der hochwertigen Doppel-Emaillierung der Speicher von Solarbayer im Zweischichtverfahren können Schwachstellen an der Emaillierung nie zu hundert Prozent ausgeschlossen werden. Deshalb ist ein zusätzlicher Korrosionsschutz immer unbedingt erforderlich, bspw. mittels der serienmäßig eingebauten Opferanode (Magnesiumstabanode). Im Falle, das es eine Schwachstelle in der Emaillierung gibt, schützt ein elektrochemischer Prozess den Speicher. Sobald das Wasser im Speicher die Verbindung zum Stahl hergestellt hat, beginnt das Magnesium sich aufzulösen, und die Partikel wandern zu der Fehlstelle, wo sie eine schützende Schicht herstellen und so eine Korrosion verhindern.
Wie oft muss eine Opferanode gewechselt werden?
Wie häufig eine Opferanode erneuert werden muss hängt von der Qualität der Emailliebeschichtung ab.
Da Solarbayer Speicher eine sehr hochwertige Emaillierung besitzen, kann eine Magnesiumstabanode viele Jahre arbeiten.
Nichtsdestotrotz ist eine regelmäßige Kontrolle unerlässlich, wir empfehlen die Anodenprüfung mindestens einmal jährlich durchzuführen.
Zur Überprüfung genügt eine Sichtkontrolle. Hierzu wird die Wasserzufuhr zum Speicher abgestellt, danach kann die Anode oben herausgeschraubt
und ein Stück weit nach oben herausgezogen werden. Hat sich die Anode zu mehr als zwei Drittel aufgelöst, muss sie erneuert werden.
Alternativ kann zur Kontrolle auch ein Anodenprüfgerät verwendet werden.
Optional zur Magnesiumanode haben sich auch Fremdstromanoden bewährt, welche den Wartungsaufwand deutlich verringern
und ebenfalls einen optimalen Speicherschutz bieten.
Wie hoch ist die Legionellengefahr in Warmwasserspeichern?
Vorab: grundsätzlich ist hier die Einhaltung der Trinkwasserverordnung zu beachten. An dieser Stelle geben wir Ihnen eine Kurzinformation mit den wichtigsten Fakten zu diesem Thema. Legionellen im Leitungswasser sind bei geringen Vorkommen unbedenklich. Wenn sich die Legionellen vermehren, können Sie jedoch beim Einatmen (bspw. beim Duschvorgang) Fieber, in schweren Fällen auch eine Pneumonie (Lungenentzündung) hervorrufen. Daher ist es wichtig, eine Vermehrung zu verhindern (Legionellenschutz). Da sich die Legionellen am schnellsten bei Wassertemperaturen zwischen 30°C bis 50°C vermehren, gilt es, den Speicher Konstant auf 50°C oder höher zu erwärmen. Bei Temperaturen über 50°C ist die Vermehrung nur noch sehr langsam, bei Temperaturen ab 60°C wird die Vermehrung gestoppt. Wird der Speicher auf bis zu 70°C erwärmt, ist der Speicher frei von Legionellen (thermische Desinfektion). Gerade für Heizungsanlagen mit Biomassekesseln oder in den Sommer- und Übergangsmonaten in Kombination mit Solarthermie ist es recht einfach, die Speichertemperatur konstant auf 60°C oder höher zu erhalten, und somit einen sicheren Legionellenschutz zu erreichen. In vermieteten Mehrfamilienhäusern oder in Großanlagen mit mehreren Duschstellen gibt es zudem eine Überprüfungspflicht, welche durch die Trinkwasserverordnung geregelt wird. Auch das DVGW-Arbeitsblatt W 551 und die 3-Liter-Regel definieren die Vorgaben für den Bau von Trinkwasser-Installationen und die Einhaltung der Legionellensicherheit.