Solarbyer hygienic stratification tank HSK-SLS-500-Plus, stainless steel tube
plus shipping costs
Product data sheet
Ganzen Text anzeigen ...
Text einklappen ...
Hygienic stratified storage tank
HSK-SLS 500 PLUS, the universal heating
centre with XXL corrugated stainless
steel pipe for a high hot water pouring
capacity for legionella-safe hot water
preparation. Two large oval tube heat
exchangers for zone loading for improved
efficiency of the solar thermal system.
Patented thermohydraulic stratification
system "SLS" in the flow and return
enables an ideal heat stratification
during charging and discharge with
immediate availability of the heat. This
enables you to achieve higher efficiency
for various heat generators and
consumers. Additional connections in the
centre area with baffle plates for more
flexibility. Numerous connections for
sensors, thermometers and an electric
immersion heater. Double fire protection
fleece insulation ISO-B1-PLUS with 220mm
thickness made from recycled fibres
(Oeko-Tex® Standard 100) incl. floor
insulation for low heat loss. Rugged PVC
jacket with stainless steel quick-lock
system for easy installation. In order
to penetrate the second insulation
layer, we recommend the optionally
available connection piece extensions as
well as the B1-Plus thermometer set.
Technical data:
nominal volume: 483 litres
material: steel S235JR
corrosion protection outside: priming
height with insulation: 1840 mm
height without insulation: 1645 mm
tilted height: 1700 mm
diameter without insulation: 650 mm
diameter with insulation: 1090 mm
weight: 158 kg
max. operating pressure: 6 bar
max. operating temperature: 95 °C
Heat exchanger DHW (inox):
surface: 7.2 m²
capacity: 62 litres
material: Stainless steel 1.4404, DVGW
diameter: 48 mm
max. operating pressure: 8 bar
max. operating temperature: 95 °C
Heat exchangers (heating / solar):
surface top: 1.3 m²
surface bottom: 2.3 m²
capacity top: 6.2 litres
capacity bottom: 10.4 litres
max. operating pressure: 10 bar
max. operating temperature: 110 °C
Connections:
heating: 8x DN40 (1 1/2")
immersion heater*: 1x DN40 (1 1/2")
*max. installation length: 500 mm
air vent: 1x DN40 (1 1/2")
sensor (top): 1x DN15 (1/2")
sensors: 4x DN15 (1/2")
DHW: 2x DN32 (1 1/4")
heat exchanger: 4x DN25 (1")
connections aligned in 90 degrees
Thermal insulation:
material: Polyester fibre fleece
lambda λ: 0.0368 W/(mK)
thickness: 220 mm +/- 10%
protective sheath: PVC foil silver
fire protection class according to
DIN 4102 for the complete insulation: B1
Standby energy consumption according to
DIN EN 12897:2020-05: 1,37 kWh/24h
standing heat loss: 57 W
energy efficiency class: A