Solarbayer hygienic stratification tank HSK-SLS-2200, stainless steel tube
plus shipping costs
Ganzen Text anzeigen ...
Text einklappen ...
Hygienic stratification buffer tank
HSK-SLS 2200, the universal heating
centre with XXL corrugated stainless
steel pipe for a high hot water pouring
capacity for legionella-safe hot water
preparation. Two large oval tube heat
exchangers for zone loading for improved
efficiency of the solar thermal system.
Patented thermohydraulic stratification
system "SLS" in the flow and return
enables an ideal heat stratification
during charging and discharge with
immediate availability of the heat. This
enables you to achieve higher efficiency
for various heat sources and consumers.
Additional connections in the centre
area with baffle plates for more
flexibility. Numerous connections for
sensors, thermometers and an electric
immersion heater. Fire protection ISO-B1
fleece insulation made from recycled
fibres (Oeko-Tex® Standard 100) incl.
floor insulation for low heat loss.
Rugged PVC jacket with stainless
steel quick-lock system for easy
installation.
Technical data:
nominal volume: 2204 litres
material: steel S235JR
corrosion protection outside: priming
height with insulation: 2170 mm
height without insulation: 2095 mm
tilted height: 2300 mm
diameter without insulation: 1250 mm
diameter with insulation: 1450 mm
weight: 413 kg
max. operating pressure: 6 bar
max. operating temperature: 95 °C
Heat exchanger DHW (inox):
surface: 12 m²
capacity: 105 litres
material: Stainless steel 1.4404, DVGW
diameter: 48 mm
max. operating pressure: 8 bar
max. operating temperature: 95 °C
Heat exchangers (heating/solar):
surface top: 4.2 m²
surface bottom: 5.5 m²
capacity top: 19.1 litres
capacity bottom: 25.1 litres
max. operating pressure: 10 bar
max. operating temperature: 110 °C
Connections:
heating: 4x DN50 (2")
heating: 4x DN40 (1 1/2")
immersion heater*: 1x DN40 (1 1/2")
*max. installation length: 850 mm
air vent: 1x DN40 (1 1/2")
sensor (top): 1x DN15 (1/2")
sensors: 4x DN15 (1/2")
DHW: 2x DN32 (1 1/4")
heat exchanger: 4x DN25 (1")
connections aligned in 90 degrees
Thermal insulation:
material: Polyester fibre fleece
lambda λ: 0.0368 W/(mK)
thickness: 100 mm +/- 10%
protective sheath: PVC foil silver
fire protection class according to
DIN 4102 for the complete insulation: B1
Standby energy consumption according to
DIN EN 12897:2020-05: 4,54 kWh/24h
standing heat loss: 189 W