Description:
wood gasification boiler for wood logs 0,7 m,
boiler steel flame-swept parts 6 mm,
large fuel chamber 310L, downward combustion
control unit with digital display
for easy handling
Technical specifications:
width/height/depth: 785 x 1420 x 1260 mm
nominal boiler output: 60 kW
efficiency factor: 92,05%
water capacity: 180 l
max. log length: 700 mm
fuel chamber capacity: 310 l
draft requirement: 15-25 Pa
max. operating pressure: 3 bar
weight: 790 kg
exhaust gas neck: 196 mm
modulating exhaust gas temp.: 150-210 C
DIN EN 303-5: 2012-10

Description:
charging unit for all popular boiler
sizes up to 120 kW nominal output
electronically controlled
(opening temperature.: 70 Gr.C)
circulation pump:
Wilo Stratos PARA RS 30/1-8
technical datas:
connection: 1 1/4" IG
Max. pressure: 6 bar
Max. temperature: 95 Gr.C
mixer motor with conrol unit
in insulation box
dimension: 300 x 370 x 235
distance tubular axle: 125 mm

Description:
device for overheating protection
of boilers.
length of capillary tube: 1300 mm
min. operating temperature: - 10 C
max. operating temperature: 110 C
temp. reponse point: 97 C +/- 2 C
operating overpressure: 10 Bar
max. performance: 6,5 m3/h

Description:
patented thermohydraulic stratification
control system (SLS). The SLS system in
the flow and return line enable ideal
heat stratification during loading and
unloading with instant heat availability.
For higher efficiency with different
heat sources and consumers. Numerous
connections for sensors, thermometers
and an immersion heater. Fire protection
fleece insulation ISO-B1 made from
recycled fibres (Oeko-Tex® Standard 100)
incl. floor insulation for low heat loss.
Robust PVC jacket with stainless steel
quick-lock system for easy installation.
Technical data:
nominal volume: 2219 litres
material: steel S235JR
corrosion protection outside: priming
height with insulation: 2170 mm
height without insulation: 2095 mm
tilted height: 2300 mm
diameter without insulation: 1250 mm
diameter with insulation: 1450 mm
weight: 258 kg
max. operating pressure: 6 bar
max. operating temperature: 95 °C
Connections:
heating: 4x DN50 (2")
immersion heater*: 1x DN40 (1 1/2")
*max. installation length: 1300 mm
air vent: 1x DN40 (1 1/2")
sensor (top): 1x DN15 (1/2")
sensors: 4x DN15 (1/2")
connections aligned in 90 degrees
Thermal insulation:
material: fibre mat
lambda λ: 0.0368 W/(mK)
thickness uncompressed: 100 mm +/- 10%
protective sheath: PVC foil silver
fire protection class according to
DIN 4102 for the complete insulation: B1
Standby energy consumption according to
DIN EN 12897:2020-05: 4.39 kWh/24h
standing heat loss: 183 W

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 1 1/4" external thread (bottom)
with pedestal
diameter: 750 mm
height: 1438 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for replacing the expansion vessel
without draining the heating system

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 3/4" external thread (on top)
with pedestal
diameter: 365 mm
height: 564 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for exchanging the expansion vessel with
draining the heating system

Description:
Absorption air separator for closed hot
and cold water systems up to a
maximum temperature of 120 °C
and an overpressure of 10 bar
variable mounting is possible
horizontal and vertical
dimension incl. insulation:
mounting length 129mm
height incl. insulation 279mm
depht incl. insulation 224mm

Description:
installation length 129mm
high 285mm
installation: vertical / horizontal (rotatable)
incl. magnetic element
min./max. temperature.: -10 °C / 120 °C.
max. pressure 10 bar
unique flow velocities up to 3 m/s.
20mm EPP insulation 0,036 W/mK

Description:
for boiler sizes up to 100 kW is used
for displaying the pressure, de-airing
and for the safeguarding of closed
hot water systems.
connection: DN 25 (1" IG)
manometer display range: 0-4 bar
automatic air vent
safety valve 3 bar
incl. insulation box
Questions about this product
question asked on 14.08.2020
vielen Dank für Ihre Anfrage.
Für die Regelung der Heizkreise und der Boilerbeladung gibt es bei uns autarke Lösungen.
Sehen Sie hierzu unsere Heizungsregler unter folgenden Links:
https://www.solarbayer.de/shop/produkte/heizungszubehoer/heizungsregelungen/solarbayer-heizungsregler-d30-witterungsgefuehrt-mit-digitalem-display
https://www.solarbayer.de/shop/produkte/heizungszubehoer/heizungsregelungen/solarbayer-heizungsregler-d10-witterungsgefuehrt-mit-digitalem-display
On 14.08.2020 by Solarbayer