Solarbayer wood log boiler set HVS E 25-1A type A (1x SLS-1000)


Free shipping in German mainland
Im Paket enthalten:

Description:
(Economic) with a nominal heat output
of 25,0 kW. Large filling chamber for
logs up to 50 cm in length, upper wood
gasification with lower burn-off,
optimised combustion chamber geometry
with primary air preheating, boiler
control with digital display for easy
operation, combustion-optimised output
and combustion control without lambda
probe for lowest emissions, easy
cleaning possible from the front,
speed-controlled forced draft fan,
exhaust gas turbulators, accumulator
sensor, (carbonization gas extraction
available as optional accessory)
Technical specifications:
nominal output 25.0 kW
efficiency: 91,4 %
energy efficiency class: A+
energy efficiency index EEI: 116
annual space heating efficiency: 79 %
boiler class DIN EN 303-5+A1: 5
width/height/depth: 645x1155x1070 mm
boiler weight: 440 kg
boiler water capacity: 75 l
max. operating temp.: 95 C
max. operating pressure: 3 bar
filling volume: 116 l
filling opening (W/H): 435 mm x 255 mm
max. log length: 500 mm
burning time, hardwood: approx. 4,2 hrs
flue gas connection: 159 mm
exhaust gas temperature: 171,9 C
necessary feed pressure: -13 ... -15 Pa
flow/return connection: 2" IT
electrical connection: 230V/50Hz/10A
recommended buffer volume: 2000 L
Only suitable for natural,
split logs with a residual
moisture of approx. 16 %

Description:
charging unit for all popular boiler
sizes up to 50 kW nominal output
electronically controlled
(opening temperature.: 70 Gr.C)
circulation pump:
Wilo PARA 25/6 SC
technical datas:
connection: 1"IG
Max. pressure: 6 bar
Max. temperature: 95 Gr.C
mixer motor with control unit
in insulation box
dimension: 300 x 370 x 235
distance tubular axle: 125 mm

Description:
device for overheating protection
of boilers.
length of capillary tube: 1300 mm
min. operating temperature: - 10 C
max. operating temperature: 110 C
temp. reponse point: 97 C +/- 2 C
operating overpressure: 10 Bar
max. performance: 6,5 m3/h

Description:
patented thermohydraulic stratification
control system (SLS). The SLS system in
the flow and return line enable ideal
heat stratification during loading and
unloading with instant heat availability.
For higher efficiency with different
heat sources and consumers. Numerous
connections for sensors, thermometers
and an immersion heater. Fire protection
fleece insulation ISO-B1 made from
recycled fibres (Oeko-Tex® Standard 100)
incl. floor insulation for low heat loss.
Robust PVC jacket with stainless steel
quick-lock system for easy installation.
Technical data:
nominal volume: 934 litres
material: steel S235JR
corrosion protection outside: priming
height with insulation: 2090 mm
height without insulation: 2015 mm
tilted height: 2100 mm
diameter without insulation: 790 mm
diameter with insulation: 990 mm
weight: 130 kg
max. operating pressure: 6 bar
max. operating temperature: 95 °C
Connections:
heating: 4x DN40 (1 1/2")
immersion heater*: 1x DN40 (1 1/2")
*max. installation length: 840 mm
air vent: 1x DN40 (1 1/2")
sensor (top): 1x DN15 (1/2")
sensors: 4x DN15 (1/2")
connections aligned in 90 degrees
Thermal insulation:
material: fibre mat
lambda λ: 0.0368 W/(mK)
thickness uncompressed: 100 mm +/- 10%
protective sheath: PVC foil silver
fire protection class according to
DIN 4102 for the complete insulation: B1
Standby energy consumption according to
DIN EN 12897:2020-05: 2.80 kWh/24h
standing heat loss: 117 W
energy efficiency class: C

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 1" external thread (on top)
with pedestal
diameter: 495 mm
height: 663 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for replacing the expansion vessel
without draining the heating system

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 3/4" external thread (on top)
with pedestal
diameter: 365 mm
height: 564 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for exchanging the expansion vessel with
draining the heating system

Description:
Absorption air separator for closed hot
and cold water systems up to a
maximum temperature of 120 °C
and an overpressure of 10 bar
variable mounting is possible
horizontal and vertical
dimension incl. insulation:
mounting length 106mm
height incl. insulation 233mm
depht incl. insulation 189mm

Description:
installation length 106mm
high 240mm
installation: vertical / horizontal (rotatable)
incl. magnetic element
min./max. temperature.: -10 °C / 120 °C.
max. pressure 10 bar
unique flow velocities up to 3 m/s.
20mm EPP insulation 0,036 W/mK

Description:
for boiler sizes up to 50 kW
is used for displaying
the pressure, de-airing and for the
safeguarding of closed hot water systems
connection: DN 25 (1" internal thread)
manometer display range: 0-4 bar
automatic air vent
safety valve: 3 bar
incl. insulation box