Solarbayer wood log boiler set HVS E 100-1C type C (2x SLS-3000-S)


Free shipping in German mainland
Im Paket enthalten:

Description:
(Economic) with a nominal heat output
of 98,0 kW. Large filling chamber for
logs up to 100 cm in length, upper wood
gasification with lower burn-off,
optimised combustion chamber geometry
with primary air preheating, boiler
control with digital display for easy
operation, combustion-optimised output
and combustion control without lambda
probe for lowest emissions, easy
cleaning possible from the front,
speed-controlled forced draft fan,
exhaust gas turbulators, accumulator
sensor, (carbonization gas extraction
available as optional accessory)
Technical specifications:
nominal output 98,0 kW
efficiency: 91,2 %
boiler class DIN EN 303-5+A1: 5
width/height/depth: 785x1440x1650 mm
boiler weight: 990 kg
boiler water capacity: 215 l
max. operating temp.: 95 C
max. operating pressure: 3 bar
filling volume: 455 l
filling opening (W/H): 575 mm x 318 mm
max. log length: 1000 mm
burning time, hardwood: approx. 4,5 hrs
flue gas connection: 196 mm
exhaust gas temperature: 226,4 C
necessary feed pressure: -13 ... -15 Pa
flow/return connection: 2" IT
electrical connection: 230V/50Hz/10A
recommended buffer volume: 6000 L
Only suitable for natural,
split logs with a residual
moisture of approx. 16 %

Description:
charging unit for all popular boiler
sizes up to 120 kW nominal output
electronically controlled
(opening temperature.: 70 Gr.C)
circulation pump:
Wilo Stratos PARA RS 30/1-8
technical datas:
connection: 1 1/4" IG
Max. pressure: 6 bar
Max. temperature: 95 Gr.C
mixer motor with conrol unit
in insulation box
dimension: 300 x 370 x 235
distance tubular axle: 125 mm

Description:
device for overheating protection
of boilers.
length of capillary tube: 1300 mm
min. operating temperature: - 10 C
max. operating temperature: 110 C
temp. reponse point: 97 C +/- 2 C
operating overpressure: 10 Bar
max. performance: 6,5 m3/h

Description:
with patented thermohydraulic
stratification control system (SLS). The
SLS system in the flow and return line
enable ideal heat stratification during
loading and unloading with instant heat
availability. For higher efficiency with
different heat sources and consumers.
Integrated large heat exchanger for
improved efficiency of the solar thermal
systems. Numerous connections for
sensors, thermometers and an immersion
heater. Fire protection fleece
insulation ISO-B1 made from recycled
fibres (Oeko-Tex® Standard 100) incl.
floor insulation for low heat loss.
Robust PVC jacket with stainless steel
quick-lock system for easy installation.
Technical data:
nominal volume: 2914 litres
material: steel S235JR
corrosion protection outside: priming
height with insulation: 2770 mm
height without insulation: 2695 mm
tilted height: 2900 mm
diameter without insulation: 1250 mm
diameter with insulation: 1450 mm
weight: 400 kg
max. operating pressure: 6 bar
max. operating temperature: 95 °C
Heat exchangers (heating/solar):
surface: 5.0 m²
capacity: 30.6 litres
max. operating pressure: 10 bar
max. operating temperature: 110 °C
Connections:
heating: 4x DN50 (2")
immersion heater*: 1x DN40 (1 1/2")
*max. installation length: 1300 mm
air vent: 1x DN40 (1 1/2")
sensor (top): 1x DN15 (1/2")
sensors: 4x DN15 (1/2")
heat exchanger: 2x DN25 (1")
connections aligned in 90 degrees
Thermal insulation:
material: fibre mat
lambda λ: 0.0368 W/(mK)
thickness uncompressed: 100 mm +/- 10%
protective sheath: PVC foil silver
fire protection class according to
DIN 4102 for the complete insulation: B1
Standby energy consumption according to
DIN EN 12897:2020-05: 5.41 kWh/24h
standing heat loss: 225 W
ATTENTION:
You have to provide either a crane,
a fork lift or a front end loader to
guarantee the unloading of the tank.

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 1" external thread (bottom)
with pedestal
diameter: 650 mm
height: 1212 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for replacing the expansion vessel
without draining the heating system

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 3/4" external thread (on top)
with pedestal
diameter: 365 mm
height: 564 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for exchanging the expansion vessel with
draining the heating system

Description:
Absorption air separator for closed hot
and cold water systems up to a
maximum temperature of 120 °C
and an overpressure of 10 bar
variable mounting is possible
horizontal and vertical
dimension incl. insulation:
mounting length 129mm
height incl. insulation 279mm
depht incl. insulation 224mm

Description:
installation length 129mm
high 285mm
installation: vertical / horizontal (rotatable)
incl. magnetic element
min./max. temperature.: -10 °C / 120 °C.
max. pressure 10 bar
unique flow velocities up to 3 m/s.
20mm EPP insulation 0,036 W/mK

Description:
for boiler sizes up to 100 kW is used
for displaying the pressure, de-airing
and for the safeguarding of closed
hot water systems.
connection: DN 25 (1" IG)
manometer display range: 0-4 bar
automatic air vent
safety valve 3 bar
incl. insulation box