Solarbayer wood log boiler set BioX 20 - 3A type A (1x SLS-1500)


Free shipping in German mainland
Im Paket enthalten:

Description:
split logs with large fuel chamber for
long burning periods. Energy-saving
combustion with the aid of a double
cyclone combustion chamber made of high
temperature silicon carbide (SiC),
as well as an optimized wood log boiler
technology with high efficiency factor.
Speed controlled induced draft fan for
best possible smoke suction even during
heating-up and stoking the wood.
Central control unit with graphic
display for the control of the boiler
charging unit temperature and the
management of the buffer tank.
Heating and refill possible without
operation of the control system, due
to the intelligent door contact sensor.
Optimisation of the combustion with the
aid of a servomotor for the permanent
control of primary and secondary air
and a lambda sensor. Comfortable
heating up due to the separate heating
door. Little heat loss due to all-over
efficient insulation. Little cleaning effort
because of half-automatic cleaning of
the heat exchanger (optional available
with fully automatic cleaning). Robust
front door and stainless-steel plates
available as optional accessories.
Technical specifications:
nominal output: 19,4 kW
efficiency: 90,6 %
energy efficiency class: A+
energy efficiency index EEI: 118
annual space-heating efficiency: 81 %
boiler class according to DIN EN 303-5+A1: 5
width/height/depth: 610 x 1365 x 1255 mm
boiler weight: 461 kg
boiler water capacity: 77 l
max. operating temp.: 90 C
max. operating pressure: 3 bar
filling volume: 125 l
filling opening (W/H): 400 mm x 260 mm
max. log length: 550 mm
burning time with hardwood: approx. 5 hrs.
flue gas connection: 150 mm (rotatable 0-135°)
exhaust gas temperature: 225 °C
necessary feed pressure: 10-15 Pa
flow/return connection: 1" IG
electrical connection: 230V/50Hz/10A
recommended buffer volume: 2000 L
Only suitable for natural, split logs with a
residual moisture of approx. 16%.

Description:
charging unit for all boiler
sizes up to 50 kW nominal output
electronically controlled (motor
regulated by boiler for mixing temp.)
circulation pump:
WITA 25-40/60
technical datas:
connection: 1 1/4"AG
Max. pressure: 6 bar
Max. temperature: 95 Gr.C
mixer motor
in insulation box
incl. two ball valves
with thermometer

Description:
Solarbayer boiler charging unit Laddomix.

Description:
device for overheating protection
of boilers.
length of capillary tube: 1300 mm
min. operating temperature: - 10 C
max. operating temperature: 110 C
temp. reponse point: 97 C +/- 2 C
operating overpressure: 10 Bar
max. performance: 6,5 m3/h

Description:
patented thermohydraulic stratification
control system (SLS). The SLS system in
the flow and return line enable ideal
heat stratification during loading and
unloading with instant heat availability.
For higher efficiency with different
heat sources and consumers. Numerous
connections for sensors, thermometers
and an immersion heater. Fire protection
fleece insulation ISO-B1 made from
recycled fibres (Oeko-Tex® Standard 100)
incl. floor insulation for low heat loss.
Robust PVC jacket with stainless steel
quick-lock system for easy installation.
Technical data:
nominal volume: 1505 litres
material: steel S235JR
corrosion protection outside: priming
height with insulation: 2220 mm
height without insulation: 2145 mm
tilted height: 2250 mm
diameter without insulation: 1000 mm
diameter with insulation: 1200 mm
weight: 193 kg
max. operating pressure: 6 bar
max. operating temperature: 95 °C
Connections:
heating: 4x DN40 (1 1/2")
immersion heater*: 1x DN40 (1 1/2")
*max. installation length: 1050 mm
air vent: 1x DN40 (1 1/2")
sensor (top): 1x DN15 (1/2")
sensors: 4x DN15 (1/2")
connections aligned in 90 degrees
Thermal insulation:
material: fibre mat
lambda λ: 0.0368 W/(mK)
thickness uncompressed: 100 mm +/- 10%
protective sheath: PVC foil silver
fire protection class according to
DIN 4102 for the complete insulation: B1
Standby energy consumption according to
DIN EN 12897:2020-05: 3.61 kWh/24h
standing heat loss: 150 W
energy efficiency class: C

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 1" external thread (on top)
with pedestal
diameter: 550 mm
height: 795 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for replacing the expansion vessel
without draining the heating system

Description:
for closed heating systems
manufactured according to UNI EN9001, DIN tested,
Certification according to
pressure equipment directive 97/23/EC
operating temperature: -10 C / +100 C
max. operating pressure: 8 bar
pre-pressure: 1,5 bar
connection: 3/4" external thread (on top)
with pedestal
diameter: 365 mm
height: 564 mm

Description:
connection and draining
for expansion vessels according to DIN 4751,
for exchanging the expansion vessel with
draining the heating system

Description:
for boiler sizes up to 50 kW
is used for displaying
the pressure, de-airing and for the
safeguarding of closed hot water systems
connection: DN 25 (1" internal thread)
manometer display range: 0-4 bar
automatic air vent
safety valve: 3 bar
incl. insulation box

Description:
Absorption air separator for closed hot
and cold water systems up to a
maximum temperature of 120 °C
and an overpressure of 10 bar
variable mounting is possible
horizontal and vertical
dimension incl. insulation:
mounting length 106mm
height incl. insulation 233mm
depht incl. insulation 189mm

Description:
installation length 106mm
high 240mm
installation: vertical / horizontal (rotatable)
incl. magnetic element
min./max. temperature.: -10 °C / 120 °C.
max. pressure 10 bar
unique flow velocities up to 3 m/s.
20mm EPP insulation 0,036 W/mK